[Archivist's note: Retrieved from http://www.icp-vortex.com/german/support/faq/laststat.txt .] Last Status of Physical Drives ============================== Example for SCSI protocol Last Status (used by parallel sCSI and Fibre channel devices): e.g. 0X24007005 | | | | | | | | | |-- 05 = SCSI-Sense key sense code / ICP Firmware Code | | | | | | | |-- 70 or 71 = SCSI-Sense Code (message from SCSI device) | | | 01 = ICP Firmware Message (message from controller) | | | 00 = SCSI Status (status of SCSI device) | | | | | |-- 00 = SCSI-ASCQ (Additional Sense Code Qualifier) | | | |-- 24 = SCSI-ASC (Additional Sense Code) | |-- 0x = indicates hex format Example for non SCSI devices (used by SATA devices) e.g. 0XFFFF7003 | | | | | | | | | | | |-- 7003 = device medium error | | | | | | | | | | | |-- FFFF = identifies non SCSI error (used for SATA devices) | |-- 0x = indicates hex format SCSI Status of the Device according to SCSI-II Specification ============================================================ 0x00000000 STATUS GOOD 0x00000002 CHECK CONDITION - not correct processed command 0x00000004 CONDITION MET - requested operation was necessary 0x00000005 ILLEGAL REQUEST - internal device error after CHECK CONDITION 0x00000006 Combination of 0x000000002 and 0x000000004 0x00000008 SCSI Device is BUSY - the last command was not accepted (after 3-5 retries, no delay between retries) (hard disks usually do not send BUSY) 0x0000000C Drive not Ready 0x0000000D Medium Fehler 0x00000010 INTERMEDIATE - a command in a series of linked commands 0x00000014 INTERMEDIATE_CONDITION MET - comb. of INT. a. COND. 0x00000018 RESERVATION_CONFLICT - device reserved by other initiator 0x00000022 COMMAND TERMINATED - SCSI command terminated by device 0x00000028 QUEUE FULL - Tagged Queue list full ICP Firmware Message Code ========================= 0x00000100 NO_VALID_RESULT 0x00000101 DRIVER_ERROR - internal error in SCSI kernel 0x00000102 UNEXPECTED_PHASE - change between command- and dataphase 0x00000103 UNEXPECTED_MESSAGE - vendor specific 0x00000104 INCOMPLETE_MESSAGE 0x00000105 GROSS_ERROR - int. SIOP error (Sync Transfer: FIFO full) 0x00000106 PHASE_MISMATCH 0x00000107 SELECTION_TIMEOUT - reset: 250 msec, power on: 10 sec 0x00000108 UNEXPECTED_DISCONNECT 0x00000109 BUS RESET - reset on SCSI bus, origin unknown 0x0000010A PARITY_ERROR 0x0000010B ABORT_CONDITION 0x0000010B WATCHDOG_TIMEOUT 0x0000010C ABORT_CONDITION 0x0000010D ILLEGAL_INSTRUCTION 0x0000010E TARGET_RESET 0x0000010F DISCONNECT_TIMEOUT - 30 sec (turn Disconnect OFF) 0x00000110 CONNECT_TIMEOUT - SIOP longer than 10 sec on SCSI bus 0x00000111 LUN_FAILURE 0x00000112 LINK_FAILURE 0x00000113 DMA_PARITY_ERROR - DMA error on internal PCI bus of GDT-Rx 0x00000114 DMA_BUS_FAULT - PCI bus fault on internal PCI bus of GDT-Rx 0x00000115 FC_MEM_ERROR - not enogh memory for Fibre Channel 'P-channel' (internal error) 0x00000116 FC_BUSY_TIMEOUT - FC-IO's in command queue are chanceled because of a timeout 0x00000117 FC_LINK_ERROR - Physical Error und Fibre Channel (e.g. loop is open or cable defective) 0x00000118 FC_IO_PARAM_ERROR - Inconsistencies in FC-IO parameters 0x00000119 SBMC_DETECTED - SCSI Bus Mode Change occured (only 53C895 LVDS SCSI chip) 0x0000011A SBMC_TIMEOUT - after SCSI Mode Change the SCSI bus does not run stable (only 53C895 LVDS) 0x0000011B DATA_OVERRUN_ERROR 0x0000011C SCSI_TRANSPORT_MODE_CHANGE 0x0000011D SGL_SIZE_EXCEEDED 0x0000011E DATA_UNDERRUN_ERROR 0x0000011F SGL_ELEMENT_SIZE_EXCEEDED 0x00000120 PASSIVE_BUS_RESET - aborted IO due to SCSI bus reset, not caused this IO 0xFFFF???? identifies non SCSI error (used for SATA devices) 0xFFFF7003 device medium error on non-SCSI device (e.g. SATA disk) SCSI Sense Key and Sense Code Definitions (according SCSI-II Spec.) =================================================================== 0h NO SENSE. Indicates that there is no specific sense key information to be reported for the designated logical unit. This would be the case for a successful command or a command that received CHECK CONDITION or COMMAND TERMINATED status because one of the filemark, EOM, or ILI bits is set to one. 1h RECOVERED ERROR. Indicates that the last command completed successfully with some recovery action performed by the target. Details may be determinable by examining the additional sense bytes and the information field. When multiple recovered errors occur during one command, the choice of which error to report (first, last, most severe, etc.) is device specific. 2h NOT READY. Indicates that the logical unit addressed cannot be accessed. Operator intervention may be required to correct this condition. 3h MEDIUM ERROR. Indicates that the command terminated with a non recovered error condition that was probably caused by a flaw in the medium or an error in the recorded data. This sense key may also be returned if the target is unable to distinguish between a flaw in the medium and a specific hardware failure (sense key 4h) 4h HARDWARE ERROR. Indicates that the target detected a non- recoverable hardware failure (for example, controller failure, device failure, parity error, etc.) while performing the command or during a self test. 5h ILLEGAL REQUEST. Indicates that there was an illegal parameter in the command descriptor block or in the additional parameters supplied as data for some commands (FORMAT UNIT, SEARCH DATA, etc.). If the target detects an invalid parameter in the command descriptor block, then it shall terminate the command without altering the medium. If the target detects an invalid parameter in the additional parameters supplied as data, then the target may have already altered the medium. This sense key may also indicate that an invalid IDENTIFY message was received (6.6.7). 6h UNIT ATTENTION. Indicates that the removable medium may have been changed or the target has been reset. See 7.9 for more detailed information about the unit attention condition. 7h DATA PROTECT. Indicates that a command that reads or writes the medium was attempted on a block that is protected from this operation. The read or write operation is not performed. 8h BLANK CHECK. Indicates that a write-once device or a sequential access device encountered blank medium or format- defined end-of-data indication while reading or a write-once device encountered a non-blank medium while writing. 9h VENDOR-SPECIFIC. This sense key is available for reporting vendor specific conditions. Ah COPY ABORTED. Indicates a COPY, COMPARE, or COPY AND VERIFY command was aborted due to an error condition on the source device, the destination device, or both. (See 8.2.3.2 for additional information about this sense key.) Bh ABORTED COMMAND. Indicates that the target aborted the command. The initiator may be able to recover by trying the command again. Ch EQUAL. Indicates a SEARCH DATA command has satisfied an equal comparison. Dh VOLUME OVERFLOW. Indicates that a buffered peripheral device has reached the end-of-partition and data may remain in the buffer that has not been written to the medium. A RECOVER BUFFERED DATA command(s) may be issued to read the unwritten data from the buffer. Eh MISCOMPARE. Indicates that the source data did not match the data read from the medium. Fh RESERVED. ASC and ASCQ assignments ======================== (new - includes SCSI-III messages!) D- DIRECT ACCESS DEVICE (SBC) Device Column key . T - SEQUENTIAL ACCESS DEVICE (SSC) blank = code not used . L - PRINTER DEVICE (SSC) not blank = code used . P- PROCESSOR DEVICE (SPC) . . W- WRITE ONCE READ MULTIPLE DEVICE (SBC) . . R- CD DEVICE (MMC) . . S- SCANNER DEVICE (SCSI-2) . . . O- OPTICAL MEMORY DEVICE (SBC) . . . M- MEDIA CHANGER DEVICE (SMC) . . . C - COMMUNICATION DEVICE (SSC) ....A- STORAGE ARRAY DEVICE (SCC) .... E- ENCLOSURE SERVICES DEVICE (SES) .... B- SIMPLIFIED DIRECT-ACCESS DEVICE (RBC) ..... ASC ASCQ D T L PWR S OMC A E B Description -------------------------------------------------------------------------- 00 00 D T L PWR S OMC A E B NO ADDITIONAL SENSE INFORMATION 00 01 T FILEMARK DETECTED 00 02 T S END-OF-PARTITION/MEDIUM DETECTED 00 03 T SETMARK DETECTED 00 04 T S BEGINNING-OF-PARTITION/MEDIUM DETECTED 00 05 T L S END-OF-DATA DETECTED 00 06 D T L PWR S OMC A E B I/O PROCESS TERMINATED 00 11 R AUDIO PLAY OPERATION IN PROGRESS 00 12 R AUDIO PLAY OPERATION PAUSED 00 13 R AUDIO PLAY OPERATION SUCCESSFULLY COMPLETED 00 14 R AUDIO PLAY OPERATION STOPPED DUE TO ERROR 00 15 R NO CURRENT AUDIO STATUS TO RETURN 00 16 D T L PWR S OMC A E B OPERATION IN PROGRESS 00 17 D T L WR S OM A E B CLEANING REQUESTED 01 00 D W O B NO INDEX/SECTOR SIGNAL 02 00 D WR OM B NO SEEK COMPLETE 03 00 D T L W S O B PERIPHERAL DEVICE WRITE FAULT 03 01 T NO WRITE CURRENT 03 02 T EXCESSIVE WRITE ERRORS 04 00 D T L PWR S OMC A E B LOGICAL UNIT NOT READY, CAUSE NOT REPORTABLE 04 01 D T L PWR S OMC A E B LOGICAL UNIT IS IN PROCESS OF BECOMING READY 04 02 D T L PWR S OMC A E B LOGICAL UNIT NOT READY, INITIALIZING CMD. REQUIRED 04 03 D T L PWR S OMC A E B LOGICAL UNIT NOT READY, MANUAL INTERVENTION REQUIRED 04 04 D T L O B LOGICAL UNIT NOT READY, FORMAT IN PROGRESS 04 05 D T W OMC A B LOGICAL UNIT NOT READY, REBUILD IN PROGRESS 04 06 D T W OMC A B LOGICAL UNIT NOT READY, RECALCULATION IN PROGRESS 04 07 D T L PWR S OMC A E B LOGICAL UNIT NOT READY, OPERATION IN PROGRESS 04 08 R LOGICAL UNIT NOT READY, LONG WRITE IN PROGRESS 05 00 D T L WR S OMC A E B LOGICAL UNIT DOES NOT RESPOND TO SELECTION 06 00 D WR OM B NO REFERENCE POSITION FOUND 07 00 D T L WR S OM B MULTIPLE PERIPHERAL DEVICES SELECTED 08 00 D T L WR S OMC A E B LOGICAL UNIT COMMUNICATION FAILURE 08 01 D T L WR S OMC A E B LOGICAL UNIT COMMUNICATION TIME-OUT 08 02 D T L WR S OMC A E B LOGICAL UNIT COMMUNICATION PARITY ERROR 08 03 D T R OM B LOGICAL UNIT COMMUNICATION CRC ERROR (ULTRA-DMA/32) 09 00 D T WR O B TRACK FOLLOWING ERROR 09 01 WR O TRACKING SERVO FAILURE 09 02 WR O FOCUS SERVO FAILURE 09 03 WR O SPINDLE SERVO FAILURE 09 04 D T WR O B HEAD SELECT FAULT 0A 00 D T L PWR S OMC A E B ERROR LOG OVERFLOW 0B 00 D T L PWR S OMC A E B WARNING 0B 01 D T L PWR S OMC A E B WARNING - SPECIFIED TEMPERATURE EXCEEDED 0B 02 D T L PWR S OMC A E B WARNING - ENCLOSURE DEGRADED 0C 00 T R S WRITE ERROR 0C 01 WRITE ERROR - RECOVERED WITH AUTO REALLOCATION 0C 02 D W O B WRITE ERROR - AUTO REALLOCATION FAILED 0C 03 D W O B WRITE ERROR - RECOMMEND REASSIGNMENT 0C 04 D T W O B COMPRESSION CHECK MISCOMPARE ERROR 0C 05 D T W O B DATA EXPANSION OCCURRED DURING COMPRESSION 0C 06 D T W O B BLOCK NOT COMPRESSIBLE 0C 07 R WRITE ERROR - RECOVERY NEEDED 0C 08 R WRITE ERROR - RECOVERY FAILED 0C 09 R WRITE ERROR - LOSS OF STREAMING 0C 0A R WRITE ERROR - PADDING BLOCKS ADDED 0D 00 0E 00 0F 00 10 00 D W O B ID CRC OR ECC ERROR 11 00 D T WR S O B UNRECOVERED READ ERROR 11 01 D T W S O B READ RETRIES EXHAUSTED 11 02 D T W S O B ERROR TOO LONG TO CORRECT 11 03 D T W S O B MULTIPLE READ ERRORS 11 04 D W O B UNRECOVERED READ ERROR - AUTO REALLOCATE FAILED 11 05 WR O B L-EC UNCORRECTABLE ERROR 11 06 WR O B CIRC UNRECOVERED ERROR 11 07 W O B DATA RE-SYNCHRONIZATION ERROR 11 08 T INCOMPLETE BLOCK READ 11 09 T NO GAP FOUND 11 0A D T O B MISCORRECTED ERROR 11 0B D W O B UNRECOVERED READ ERROR - RECOMMEND REASSIGNMENT 11 0C D W O B UNRECOVERED READ ERROR - RECOMMEND REWRITE THE DATA 11 0D D T WR O B DE-COMPRESSION CRC ERROR 11 0E D T WR O B CANNOT DECOMPRESS USING DECLARED ALGORITHM 11 0F R ERROR READING UPC/EAN NUMBER 11 10 R ERROR READING ISRC NUMBER 11 11 R READ ERROR - LOSS OF STREAMING 12 00 D W O B ADDRESS MARK NOT FOUND FOR ID FIELD 13 00 D W O B ADDRESS MARK NOT FOUND FOR DATA FIELD 14 00 D T L WR S O B RECORDED ENTITY NOT FOUND 14 01 D T WR O B RECORD NOT FOUND 14 02 T FILEMARK OR SETMARK NOT FOUND 14 03 T END-OF-DATA NOT FOUND 14 04 T BLOCK SEQUENCE ERROR 14 05 D T W O B RECORD NOT FOUND - RECOMMEND REASSIGNMENT 14 06 D T W O B RECORD NOT FOUND - DATA AUTO-REALLOCATED 15 00 D T L WR S OM B RANDOM POSITIONING ERROR 15 01 D T L WR S OM B MECHANICAL POSITIONING ERROR 15 02 D T WR O B POSITIONING ERROR DETECTED BY READ OF MEDIUM 16 00 D W O B DATA SYNCHRONIZATION MARK ERROR 16 01 D W O B DATA SYNC ERROR - DATA REWRITTEN 16 02 D W O B DATA SYNC ERROR - RECOMMEND REWRITE 16 03 D W O B DATA SYNC ERROR - DATA AUTO-REALLOCATED 16 04 D W O B DATA SYNC ERROR - RECOMMEND REASSIGNMENT 17 00 D T WR S O B RECOVERED DATA WITH NO ERROR CORRECTION APPLIED 17 01 D T WR S O B RECOVERED DATA WITH RETRIES 17 02 D T WR O B RECOVERED DATA WITH POSITIVE HEAD OFFSET 17 03 D T WR O B RECOVERED DATA WITH NEGATIVE HEAD OFFSET 17 04 WR O B RECOVERED DATA WITH RETRIES AND/OR CIRC APPLIED 17 05 D WR O B RECOVERED DATA USING PREVIOUS SECTOR ID 17 06 D W O B RECOVERED DATA WITHOUT ECC - DATA AUTO-REALLOCATED 17 07 D W O B RECOVERED DATA WITHOUT ECC - RECOMMEND REASSIGNMENT 17 08 D W O B RECOVERED DATA WITHOUT ECC - RECOMMEND REWRITE 17 09 D W O B RECOVERED DATA WITHOUT ECC - DATA REWRITTEN 18 00 D T WR O B RECOVERED DATA WITH ERROR CORRECTION APPLIED 18 01 D WR O B RECOVERED DATA WITH ERROR CORR. & RETRIES APPLIED 18 02 D WR O B RECOVERED DATA - DATA AUTO-REALLOCATED 18 03 R RECOVERED DATA WITH CIRC 18 04 R RECOVERED DATA WITH L-EC 18 05 D WR O B RECOVERED DATA - RECOMMEND REASSIGNMENT 18 06 D WR O B RECOVERED DATA - RECOMMEND REWRITE 18 07 D W O B RECOVERED DATA WITH ECC - DATA REWRITTEN 19 00 D O DEFECT LIST ERROR 19 01 D O DEFECT LIST NOT AVAILABLE 19 02 D O DEFECT LIST ERROR IN PRIMARY LIST 19 03 D O DEFECT LIST ERROR IN GROWN LIST 1A 00 D T L PWR S OMC A E B PARAMETER LIST LENGTH ERROR 1B 00 D T L PWR S OMC A E B SYNCHRONOUS DATA TRANSFER ERROR 1C 00 D O B DEFECT LIST NOT FOUND 1C 01 D O B PRIMARY DEFECT LIST NOT FOUND 1C 02 D O B GROWN DEFECT LIST NOT FOUND 1D 00 D T W O B MISCOMPARE DURING VERIFY OPERATION 1E 00 D W O B RECOVERED ID WITH ECC CORRECTION 1F 00 D O PARTIAL DEFECT LIST TRANSFER 20 00 D T L PWR S OMC A E B INVALID COMMAND OPERATION CODE 21 00 D T WR OM B LOGICAL BLOCK ADDRESS OUT OF RANGE 21 01 D T WR OM B INVALID ELEMENT ADDRESS 22 00 D ILLEGAL FUNCTION (USE 20 00, 24 00, OR 26 00) 23 00 24 00 D T L PWR S OMC A E B INVALID FIELD IN CDB 25 00 D T L PWR S OMC A E B LOGICAL UNIT NOT SUPPORTED 26 00 D T L PWR S OMC A E B INVALID FIELD IN PARAMETER LIST 26 01 D T L PWR S OMC A E B PARAMETER NOT SUPPORTED 26 02 D T L PWR S OMC A E B PARAMETER VALUE INVALID 26 03 D T L PWR S OMC A E THRESHOLD PARAMETERS NOT SUPPORTED 26 04 D T L PWR S OMC A E B INVALID RELEASE OF ACTIVE PERSISTENT RESERVATION 27 00 D T W O B WRITE PROTECTED 27 01 D T W O B HARDWARE WRITE PROTECTED 27 02 D T W O B LOGICAL UNIT SOFTWARE WRITE PROTECTED 27 03 T ASSOCIATED WRITE PROTECT 27 04 T PERSISTENT WRITE PROTECT 27 05 T PERMANENT WRITE PROTECT 28 00 D T L PWR S OMC A E B NOT READY TO READY CHANGE, MEDIUM MAY HAVE CHANGED 28 01 D T WR OM B IMPORT OR EXPORT ELEMENT ACCESSED 29 00 D T L PWR S OMC A E B POWER ON, RESET, OR BUS DEVICE RESET OCCURRED 29 01 D T L PWR S OMC A E B POWER ON OCCURRED 29 02 D T L PWR S OMC A E B SCSI BUS RESET OCCURRED 29 03 D T L PWR S OMC A E B BUS DEVICE RESET FUNCTION OCCURRED 29 04 D T L PWR S OMC A E B DEVICE INTERNAL RESET 29 05 D T L PWR S OMC A E B TRANSCEIVER MODE CHANGED TO SINGLE-ENDED 29 06 D T L PWR S OMC A E B TRANSCEIVER MODE CHANGED TO LVD 2A 00 D T L WR S OMC A E B PARAMETERS CHANGED 2A 01 D T L WR S OMC A E B MODE PARAMETERS CHANGED 2A 02 D T L WR S OMC A E LOG PARAMETERS CHANGED 2A 03 D T L PWR S OMC A E RESERVATIONS PREEMPTED 2B 00 D T L PWR S O C COPY CANNOT EXECUTE SINCE HOST CANNOT DISCONNECT 2C 00 D T L PWR S OMC A E B COMMAND SEQUENCE ERROR 2C 01 S TOO MANY WINDOWS SPECIFIED 2C 02 S INVALID COMBINATION OF WINDOWS SPECIFIED 2C 03 R CURRENT PROGRAM AREA IS NOT EMPTY 2C 04 R CURRENT PROGRAM AREA IS EMPTY 2D 00 T OVERWRITE ERROR ON UPDATE IN PLACE 2E 00 2F 00 D T L PWR S OMC A E B COMMANDS CLEARED BY ANOTHER INITIATOR 30 00 D T WR OM B INCOMPATIBLE MEDIUM INSTALLED 30 01 D T WR O B CANNOT READ MEDIUM - UNKNOWN FORMAT 30 02 D T WR O B CANNOT READ MEDIUM - INCOMPATIBLE FORMAT 30 03 D T CLEANING CARTRIDGE INSTALLED 30 04 D T WR O B CANNOT WRITE MEDIUM - UNKNOWN FORMAT 30 05 D T WR O B CANNOT WRITE MEDIUM - INCOMPATIBLE FORMAT 30 06 D T W O B CANNOT FORMAT MEDIUM - INCOMPATIBLE MEDIUM 30 07 D T L WR S OM A E B CLEANING FAILURE 30 08 R CANNOT WRITE - APPLICATION CODE MISMATCH 30 09 R CURRENT SESSION NOT FIXATED FOR APPEND 31 00 D T WR O B MEDIUM FORMAT CORRUPTED 31 01 D L R O B FORMAT COMMAND FAILED 32 00 D W O B NO DEFECT SPARE LOCATION AVAILABLE 32 01 D W O B DEFECT LIST UPDATE FAILURE 33 00 T TAPE LENGTH ERROR 34 00 D T L PWR S OMC A E B ENCLOSURE FAILURE 35 00 D T L PWR S OMC A E B ENCLOSURE SERVICES FAILURE 35 01 D T L PWR S OMC A E B UNSUPPORTED ENCLOSURE FUNCTION 35 02 D T L PWR S OMC A E B ENCLOSURE SERVICES UNAVAILABLE 35 03 D T L PWR S OMC A E B ENCLOSURE SERVICES TRANSFER FAILURE 35 04 D T L PWR S OMC A E B ENCLOSURE SERVICES TRANSFER REFUSED 36 00 L RIBBON, INK, OR TONER FAILURE 37 00 D T L WR S OMC A E B ROUNDED PARAMETER 38 00 39 00 D T L WR S OMC A E SAVING PARAMETERS NOT SUPPORTED 3A 00 D T L WR S OM B MEDIUM NOT PRESENT 3A 01 D T WR OM B MEDIUM NOT PRESENT - TRAY CLOSED 3A 02 D T WR OM B MEDIUM NOT PRESENT - TRAY OPEN 3B 00 T L SEQUENTIAL POSITIONING ERROR 3B 01 T TAPE POSITION ERROR AT BEGINNING-OF-MEDIUM 3B 02 T TAPE POSITION ERROR AT END-OF-MEDIUM 3B 03 L TAPE OR ELECTRONIC VERTICAL FORMS UNIT NOT READY 3B 04 L SLEW FAILURE 3B 05 L PAPER JAM 3B 06 L FAILED TO SENSE TOP-OF-FORM 3B 07 L FAILED TO SENSE BOTTOM-OF-FORM 3B 08 T REPOSITION ERROR 3B 09 S READ PAST END OF MEDIUM 3B 0A S READ PAST BEGINNING OF MEDIUM 3B 0B S POSITION PAST END OF MEDIUM 3B 0C T S POSITION PAST BEGINNING OF MEDIUM 3B 0D D T WR OM B MEDIUM DESTINATION ELEMENT FULL 3B 0E D T WR OM B MEDIUM SOURCE ELEMENT EMPTY 3B 0F R END OF MEDIUM REACHED 3B 11 D T WR OM B MEDIUM MAGAZINE NOT ACCESSIBLE 3B 12 D T WR OM B MEDIUM MAGAZINE REMOVED 3B 13 D T WR OM B MEDIUM MAGAZINE INSERTED 3B 14 D T WR OM B MEDIUM MAGAZINE LOCKED 3B 15 D T WR OM B MEDIUM MAGAZINE UNLOCKED 3B 16 R MECHANICAL POSITIONING OR CHANGER ERROR 3C 00 3D 00 D T L PWR S OMC A E INVALID BITS IN IDENTIFY MESSAGE 3E 00 D T L PWR S OMC A E B LOGICAL UNIT HAS NOT SELF-CONFIGURED YET 3E 01 D T L PWR S OMC A E B LOGICAL UNIT FAILURE 3E 02 D T L PWR S OMC A E B TIMEOUT ON LOGICAL UNIT 3F 00 D T L PWR S OMC A E B TARGET OPERATING CONDITIONS HAVE CHANGED 3F 01 D T L PWR S OMC A E B MICROCODE HAS BEEN CHANGED 3F 02 D T L PWR S OMC B CHANGED OPERATING DEFINITION 3F 03 D T L PWR S OMC A E B INQUIRY DATA HAS CHANGED 3F 04 D T WR OMC A E B COMPONENT DEVICE ATTACHED 3F 05 D T WR OMC A E B DEVICE IDENTIFIER CHANGED 3F 06 D T WR OMC A E B REDUNDANCY GROUP CREATED OR MODIFIED 3F 07 D T WR OMC A E B REDUNDANCY GROUP DELETED 3F 08 D T WR OMC A E B SPARE CREATED OR MODIFIED 3F 09 D T WR OMC A E B SPARE DELETED 3F 0A D T WR OMC A E B VOLUME SET CREATED OR MODIFIED 3F 0B D T WR OMC A E B VOLUME SET DELETED 3F 0C D T WR OMC A E B VOLUME SET DEASSIGNED 3F 0D D T WR OMC A E B VOLUME SET REASSIGNED 40 00 D RAM FAILURE (SHOULD USE 40 NN) 40 NN D T L PWR S OMC A E B DIAGNOSTIC FAILURE ON COMPONENT NN (80H-FFH) 41 00 D DATA PATH FAILURE (SHOULD USE 40 NN) 42 00 D POWER-ON OR SELF-TEST FAILURE (SHOULD USE 40 NN) 43 00 D T L PWR S OMC A E B MESSAGE ERROR 44 00 D T L PWR S OMC A E B INTERNAL TARGET FAILURE 45 00 D T L PWR S OMC A E B SELECT OR RESELECT FAILURE 46 00 D T L PWR S OMC B UNSUCCESSFUL SOFT RESET 47 00 D T L PWR S OMC A E B SCSI PARITY ERROR 48 00 D T L PWR S OMC A E B INITIATOR DETECTED ERROR MESSAGE RECEIVED 49 00 D T L PWR S OMC A E B INVALID MESSAGE ERROR 4A 00 D T L PWR S OMC A E B COMMAND PHASE ERROR 4B 00 D T L PWR S OMC A E B DATA PHASE ERROR 4C 00 D T L PWR S OMC A E B LOGICAL UNIT FAILED SELF-CONFIGURATION 4D NN D T L PWR S OMC A E B TAGGED OVERLAPPED COMMANDS (NN = QUEUE TAG) 4E 00 D T L PWR S OMC A E B OVERLAPPED COMMANDS ATTEMPTED 4F 00 50 00 T WRITE APPEND ERROR 50 01 T WRITE APPEND POSITION ERROR 50 02 T POSITION ERROR RELATED TO TIMING 51 00 T O ERASE FAILURE 52 00 T CARTRIDGE FAULT 53 00 D T L WR S OM B MEDIA LOAD OR EJECT FAILED 53 01 T UNLOAD TAPE FAILURE 53 02 D T WR OM B MEDIUM REMOVAL PREVENTED 54 00 P SCSI TO HOST SYSTEM INTERFACE FAILURE 55 00 P SYSTEM RESOURCE FAILURE 55 01 D O B SYSTEM BUFFER FULL 56 00 57 00 R UNABLE TO RECOVER TABLE-OF-CONTENTS 58 00 O GENERATION DOES NOT EXIST 59 00 O UPDATED BLOCK READ 5A 00 D T L PWR S OM B OPERATOR REQUEST OR STATE CHANGE INPUT 5A 01 D T WR OM B OPERATOR MEDIUM REMOVAL REQUEST 5A 02 D T W O A B OPERATOR SELECTED WRITE PROTECT 5A 03 D T W O A B OPERATOR SELECTED WRITE PERMIT 5B 00 D T L PWR S OM LOG EXCEPTION 5B 01 D T L PWR S OM THRESHOLD CONDITION MET 5B 02 D T L PWR S OM LOG COUNTER AT MAXIMUM 5B 03 D T L PWR S OM LOG LIST CODES EXHAUSTED 5C 00 D O RPL STATUS CHANGE 5C 01 D O SPINDLES SYNCHRONIZED 5C 02 D O SPINDLES NOT SYNCHRONIZED 5D 00 D T L PWR S OMC A E B FAILURE PREDICTION THRESHOLD EXCEEDED 5D FF D T L PWR S OMC A E B FAILURE PREDICTION THRESHOLD EXCEEDED (FALSE) 5E 00 D T L PWR S O C A B LOW POWER CONDITION ON 5E 01 D T L PWR S O C A B IDLE CONDITION ACTIVATED BY TIMER 5E 02 D T L PWR S O C A B STANDBY CONDITION ACTIVATED BY TIMER 5E 03 D T L PWR S O C A B IDLE CONDITION ACTIVATED BY COMMAND 5E 04 D T L PWR S O C A B STANDBY CONDITION ACTIVATED BY COMMAND 5F 00 60 00 S LAMP FAILURE 61 00 S VIDEO ACQUISITION ERROR 61 01 S UNABLE TO ACQUIRE VIDEO 61 02 S OUT OF FOCUS 62 00 S SCAN HEAD POSITIONING ERROR 63 00 R END OF USER AREA ENCOUNTERED ON THIS TRACK 63 01 R PACKET DOES NOT FIT IN AVAILABLE SPACE 64 00 R ILLEGAL MODE FOR THIS TRACK 64 01 R INVALID PACKET SIZE 65 00 D T L PWR S OMC A E B VOLTAGE FAULT 66 00 S AUTOMATIC DOCUMENT FEEDER COVER UP 66 01 S AUTOMATIC DOCUMENT FEEDER LIFT UP 66 02 S DOCUMENT JAM IN AUTOMATIC DOCUMENT FEEDER 66 03 S DOCUMENT MISS FEED AUTOMATIC IN DOCUMENT FEEDER 67 00 A CONFIGURATION FAILURE 67 01 A CONFIGURATION OF INCAPABLE LOGICAL UNITS FAILED 67 02 A ADD LOGICAL UNIT FAILED 67 03 A MODIFICATION OF LOGICAL UNIT FAILED 67 04 A EXCHANGE OF LOGICAL UNIT FAILED 67 05 A REMOVE OF LOGICAL UNIT FAILED 67 06 A ATTACHMENT OF LOGICAL UNIT FAILED 67 07 A CREATION OF LOGICAL UNIT FAILED 67 08 A ASSIGN FAILURE OCCURRED 67 09 A MULTIPLY ASSIGNED LOGICAL UNIT 68 00 A LOGICAL UNIT NOT CONFIGURED 69 00 A DATA LOSS ON LOGICAL UNIT 69 01 A MULTIPLE LOGICAL UNIT FAILURES 69 02 A PARITY/DATA MISMATCH 6A 00 A INFORMATIONAL, REFER TO LOG 6B 00 A STATE CHANGE HAS OCCURRED 6B 01 A REDUNDANCY LEVEL GOT BETTER 6B 02 A REDUNDANCY LEVEL GOT WORSE 6C 00 A REBUILD FAILURE OCCURRED 6D 00 A RECALCULATE FAILURE OCCURRED 6E 00 A COMMAND TO LOGICAL UNIT FAILED 6F 00 70 NN T DECOMPRESSION EXCEPTION SHORT ALGORITHM ID OF NN 71 00 T DECOMPRESSION EXCEPTION LONG ALGORITHM ID 72 00 R SESSION FIXATION ERROR 72 01 R SESSION FIXATION ERROR WRITING LEAD-IN 72 02 R SESSION FIXATION ERROR WRITING LEAD-OUT 72 03 R SESSION FIXATION ERROR - INCOMPLETE TRACK IN SESSION 72 04 R EMPTY OR PARTIALLY WRITTEN RESERVED TRACK 73 00 R CD CONTROL ERROR 73 01 R POWER CALIBRATION AREA ALMOST FULL 73 02 R POWER CALIBRATION AREA IS FULL 73 03 R POWER CALIBRATION AREA ERROR 73 04 R PROGRAM MEMORY AREA UPDATE FAILURE 73 05 R PROGRAM MEMORY AREA IS FULL 74 00 75 00 76 00 77 00 78 00 79 00 7A 00 7B 00 7C 00 7D 00 7E 00 7F 00 80h xxh \ Through > Vendor-specific. FFh xxh / xxh 80h \ Through > Vendor-specific QUALIFICATION OF STANDARD ASC. xxh FFh / ALL CODES NOT SHOWN ARE RESERVED.